UDisksManagerNVMe

UDisksManagerNVMe — Generated C code for the org.freedesktop.UDisks2.Manager.NVMe D-Bus interface

Functions

Types and Values

Object Hierarchy

    GInterface
    ╰── UDisksManagerNVMe

Prerequisites

UDisksManagerNVMe requires GObject.

Description

This section contains code for working with the org.freedesktop.UDisks2.Manager.NVMe D-Bus interface in C.

Functions

udisks_manager_nvme_interface_info ()

GDBusInterfaceInfo *
udisks_manager_nvme_interface_info (void);

Gets a machine-readable description of the org.freedesktop.UDisks2.Manager.NVMe D-Bus interface.

Returns

A GDBusInterfaceInfo. Do not free.

[transfer none]


udisks_manager_nvme_override_properties ()

guint
udisks_manager_nvme_override_properties
                               (GObjectClass *klass,
                                guint property_id_begin);

Overrides all GObject properties in the UDisksManagerNVMe interface for a concrete class. The properties are overridden in the order they are defined.

Parameters

klass

The class structure for a GObject derived class.

 

property_id_begin

The property id to assign to the first overridden property.

 

Returns

The last property id.


udisks_manager_nvme_call_set_host_nqn ()

void
udisks_manager_nvme_call_set_host_nqn (UDisksManagerNVMe *proxy,
                                       const gchar *arg_hostnqn,
                                       GVariant *arg_options,
                                       GCancellable *cancellable,
                                       GAsyncReadyCallback callback,
                                       gpointer user_data);

Asynchronously invokes the SetHostNQN() D-Bus method on proxy . When the operation is finished, callback will be invoked in the thread-default main loop of the thread you are calling this method from (see g_main_context_push_thread_default()). You can then call udisks_manager_nvme_call_set_host_nqn_finish() to get the result of the operation.

See udisks_manager_nvme_call_set_host_nqn_sync() for the synchronous, blocking version of this method.

Parameters

proxy

A UDisksManagerNVMeProxy.

 

arg_hostnqn

Argument to pass with the method invocation.

 

arg_options

Argument to pass with the method invocation.

 

cancellable

A GCancellable or NULL.

[nullable]

callback

A GAsyncReadyCallback to call when the request is satisfied or NULL.

 

user_data

User data to pass to callback .

 

Since: 2.10.0


udisks_manager_nvme_call_set_host_nqn_finish ()

gboolean
udisks_manager_nvme_call_set_host_nqn_finish
                               (UDisksManagerNVMe *proxy,
                                GAsyncResult *res,
                                GError **error);

Finishes an operation started with udisks_manager_nvme_call_set_host_nqn().

Parameters

proxy

A UDisksManagerNVMeProxy.

 

res

The GAsyncResult obtained from the GAsyncReadyCallback passed to udisks_manager_nvme_call_set_host_nqn().

 

error

Return location for error or NULL.

 

Returns

TRUE if the call succeeded, FALSE if error is set.

[skip]

Since: 2.10.0


udisks_manager_nvme_call_set_host_nqn_sync ()

gboolean
udisks_manager_nvme_call_set_host_nqn_sync
                               (UDisksManagerNVMe *proxy,
                                const gchar *arg_hostnqn,
                                GVariant *arg_options,
                                GCancellable *cancellable,
                                GError **error);

Synchronously invokes the SetHostNQN() D-Bus method on proxy . The calling thread is blocked until a reply is received.

See udisks_manager_nvme_call_set_host_nqn() for the asynchronous version of this method.

Parameters

proxy

A UDisksManagerNVMeProxy.

 

arg_hostnqn

Argument to pass with the method invocation.

 

arg_options

Argument to pass with the method invocation.

 

cancellable

A GCancellable or NULL.

[nullable]

error

Return location for error or NULL.

 

Returns

TRUE if the call succeeded, FALSE if error is set.

[skip]

Since: 2.10.0


udisks_manager_nvme_complete_set_host_nqn ()

void
udisks_manager_nvme_complete_set_host_nqn
                               (UDisksManagerNVMe *object,
                                GDBusMethodInvocation *invocation);

Helper function used in service implementations to finish handling invocations of the SetHostNQN() D-Bus method. If you instead want to finish handling an invocation by returning an error, use g_dbus_method_invocation_return_error() or similar.

This method will free invocation , you cannot use it afterwards.

Parameters

object

A UDisksManagerNVMe.

 

invocation

A GDBusMethodInvocation.

[transfer full]

Since: 2.10.0


udisks_manager_nvme_call_set_host_id ()

void
udisks_manager_nvme_call_set_host_id (UDisksManagerNVMe *proxy,
                                      const gchar *arg_hostid,
                                      GVariant *arg_options,
                                      GCancellable *cancellable,
                                      GAsyncReadyCallback callback,
                                      gpointer user_data);

Asynchronously invokes the SetHostID() D-Bus method on proxy . When the operation is finished, callback will be invoked in the thread-default main loop of the thread you are calling this method from (see g_main_context_push_thread_default()). You can then call udisks_manager_nvme_call_set_host_id_finish() to get the result of the operation.

See udisks_manager_nvme_call_set_host_id_sync() for the synchronous, blocking version of this method.

Parameters

proxy

A UDisksManagerNVMeProxy.

 

arg_hostid

Argument to pass with the method invocation.

 

arg_options

Argument to pass with the method invocation.

 

cancellable

A GCancellable or NULL.

[nullable]

callback

A GAsyncReadyCallback to call when the request is satisfied or NULL.

 

user_data

User data to pass to callback .

 

Since: 2.10.0


udisks_manager_nvme_call_set_host_id_finish ()

gboolean
udisks_manager_nvme_call_set_host_id_finish
                               (UDisksManagerNVMe *proxy,
                                GAsyncResult *res,
                                GError **error);

Finishes an operation started with udisks_manager_nvme_call_set_host_id().

Parameters

proxy

A UDisksManagerNVMeProxy.

 

res

The GAsyncResult obtained from the GAsyncReadyCallback passed to udisks_manager_nvme_call_set_host_id().

 

error

Return location for error or NULL.

 

Returns

TRUE if the call succeeded, FALSE if error is set.

[skip]

Since: 2.10.0


udisks_manager_nvme_call_set_host_id_sync ()

gboolean
udisks_manager_nvme_call_set_host_id_sync
                               (UDisksManagerNVMe *proxy,
                                const gchar *arg_hostid,
                                GVariant *arg_options,
                                GCancellable *cancellable,
                                GError **error);

Synchronously invokes the SetHostID() D-Bus method on proxy . The calling thread is blocked until a reply is received.

See udisks_manager_nvme_call_set_host_id() for the asynchronous version of this method.

Parameters

proxy

A UDisksManagerNVMeProxy.

 

arg_hostid

Argument to pass with the method invocation.

 

arg_options

Argument to pass with the method invocation.

 

cancellable

A GCancellable or NULL.

[nullable]

error

Return location for error or NULL.

 

Returns

TRUE if the call succeeded, FALSE if error is set.

[skip]

Since: 2.10.0


udisks_manager_nvme_complete_set_host_id ()

void
udisks_manager_nvme_complete_set_host_id
                               (UDisksManagerNVMe *object,
                                GDBusMethodInvocation *invocation);

Helper function used in service implementations to finish handling invocations of the SetHostID() D-Bus method. If you instead want to finish handling an invocation by returning an error, use g_dbus_method_invocation_return_error() or similar.

This method will free invocation , you cannot use it afterwards.

Parameters

object

A UDisksManagerNVMe.

 

invocation

A GDBusMethodInvocation.

[transfer full]

Since: 2.10.0


udisks_manager_nvme_call_connect ()

void
udisks_manager_nvme_call_connect (UDisksManagerNVMe *proxy,
                                  const gchar *arg_subsysnqn,
                                  const gchar *arg_transport,
                                  const gchar *arg_transport_addr,
                                  GVariant *arg_options,
                                  GCancellable *cancellable,
                                  GAsyncReadyCallback callback,
                                  gpointer user_data);

Asynchronously invokes the Connect() D-Bus method on proxy . When the operation is finished, callback will be invoked in the thread-default main loop of the thread you are calling this method from (see g_main_context_push_thread_default()). You can then call udisks_manager_nvme_call_connect_finish() to get the result of the operation.

See udisks_manager_nvme_call_connect_sync() for the synchronous, blocking version of this method.

Parameters

proxy

A UDisksManagerNVMeProxy.

 

arg_subsysnqn

Argument to pass with the method invocation.

 

arg_transport

Argument to pass with the method invocation.

 

arg_transport_addr

Argument to pass with the method invocation.

 

arg_options

Argument to pass with the method invocation.

 

cancellable

A GCancellable or NULL.

[nullable]

callback

A GAsyncReadyCallback to call when the request is satisfied or NULL.

 

user_data

User data to pass to callback .

 

Since: 2.10.0


udisks_manager_nvme_call_connect_finish ()

gboolean
udisks_manager_nvme_call_connect_finish
                               (UDisksManagerNVMe *proxy,
                                gchar **out_nvme_ctrl,
                                GAsyncResult *res,
                                GError **error);

Finishes an operation started with udisks_manager_nvme_call_connect().

Parameters

proxy

A UDisksManagerNVMeProxy.

 

out_nvme_ctrl

Return location for return parameter or NULL to ignore.

[out][optional]

res

The GAsyncResult obtained from the GAsyncReadyCallback passed to udisks_manager_nvme_call_connect().

 

error

Return location for error or NULL.

 

Returns

TRUE if the call succeeded, FALSE if error is set.

[skip]

Since: 2.10.0


udisks_manager_nvme_call_connect_sync ()

gboolean
udisks_manager_nvme_call_connect_sync (UDisksManagerNVMe *proxy,
                                       const gchar *arg_subsysnqn,
                                       const gchar *arg_transport,
                                       const gchar *arg_transport_addr,
                                       GVariant *arg_options,
                                       gchar **out_nvme_ctrl,
                                       GCancellable *cancellable,
                                       GError **error);

Synchronously invokes the Connect() D-Bus method on proxy . The calling thread is blocked until a reply is received.

See udisks_manager_nvme_call_connect() for the asynchronous version of this method.

Parameters

proxy

A UDisksManagerNVMeProxy.

 

arg_subsysnqn

Argument to pass with the method invocation.

 

arg_transport

Argument to pass with the method invocation.

 

arg_transport_addr

Argument to pass with the method invocation.

 

arg_options

Argument to pass with the method invocation.

 

out_nvme_ctrl

Return location for return parameter or NULL to ignore.

[out][optional]

cancellable

A GCancellable or NULL.

[nullable]

error

Return location for error or NULL.

 

Returns

TRUE if the call succeeded, FALSE if error is set.

[skip]

Since: 2.10.0


udisks_manager_nvme_complete_connect ()

void
udisks_manager_nvme_complete_connect (UDisksManagerNVMe *object,
                                      GDBusMethodInvocation *invocation,
                                      const gchar *nvme_ctrl);

Helper function used in service implementations to finish handling invocations of the Connect() D-Bus method. If you instead want to finish handling an invocation by returning an error, use g_dbus_method_invocation_return_error() or similar.

This method will free invocation , you cannot use it afterwards.

Parameters

object

A UDisksManagerNVMe.

 

invocation

A GDBusMethodInvocation.

[transfer full]

nvme_ctrl

Parameter to return.

 

Since: 2.10.0


udisks_manager_nvme_get_host_id ()

const gchar *
udisks_manager_nvme_get_host_id (UDisksManagerNVMe *object);

Gets the value of the "HostID" D-Bus property.

Since this D-Bus property is readable, it is meaningful to use this function on both the client- and service-side.

The returned value is only valid until the property changes so on the client-side it is only safe to use this function on the thread where object was constructed. Use udisks_manager_nvme_dup_host_id() if on another thread.

[skip]

Parameters

object

A UDisksManagerNVMe.

 

Returns

The property value or NULL if the property is not set. Do not free the returned value, it belongs to object .

[transfer none][nullable]

Since: 2.10.0


udisks_manager_nvme_get_host_nqn ()

const gchar *
udisks_manager_nvme_get_host_nqn (UDisksManagerNVMe *object);

Gets the value of the "HostNQN" D-Bus property.

Since this D-Bus property is readable, it is meaningful to use this function on both the client- and service-side.

The returned value is only valid until the property changes so on the client-side it is only safe to use this function on the thread where object was constructed. Use udisks_manager_nvme_dup_host_nqn() if on another thread.

[skip]

Parameters

object

A UDisksManagerNVMe.

 

Returns

The property value or NULL if the property is not set. Do not free the returned value, it belongs to object .

[transfer none][nullable]

Since: 2.10.0


udisks_manager_nvme_dup_host_id ()

gchar *
udisks_manager_nvme_dup_host_id (UDisksManagerNVMe *object);

Gets a copy of the "HostID" D-Bus property.

Since this D-Bus property is readable, it is meaningful to use this function on both the client- and service-side.

[skip]

Parameters

object

A UDisksManagerNVMe.

 

Returns

The property value or NULL if the property is not set. The returned value should be freed with g_free().

[transfer full][nullable]

Since: 2.10.0


udisks_manager_nvme_dup_host_nqn ()

gchar *
udisks_manager_nvme_dup_host_nqn (UDisksManagerNVMe *object);

Gets a copy of the "HostNQN" D-Bus property.

Since this D-Bus property is readable, it is meaningful to use this function on both the client- and service-side.

[skip]

Parameters

object

A UDisksManagerNVMe.

 

Returns

The property value or NULL if the property is not set. The returned value should be freed with g_free().

[transfer full][nullable]

Since: 2.10.0


udisks_manager_nvme_set_host_id ()

void
udisks_manager_nvme_set_host_id (UDisksManagerNVMe *object,
                                 const gchar *value);

Sets the "HostID" D-Bus property to value .

Since this D-Bus property is not writable, it is only meaningful to use this function on the service-side.

[skip]

Parameters

object

A UDisksManagerNVMe.

 

value

The value to set.

 

Since: 2.10.0


udisks_manager_nvme_set_host_nqn ()

void
udisks_manager_nvme_set_host_nqn (UDisksManagerNVMe *object,
                                  const gchar *value);

Sets the "HostNQN" D-Bus property to value .

Since this D-Bus property is not writable, it is only meaningful to use this function on the service-side.

[skip]

Parameters

object

A UDisksManagerNVMe.

 

value

The value to set.

 

Since: 2.10.0


udisks_manager_nvme_proxy_new ()

void
udisks_manager_nvme_proxy_new (GDBusConnection *connection,
                               GDBusProxyFlags flags,
                               const gchar *name,
                               const gchar *object_path,
                               GCancellable *cancellable,
                               GAsyncReadyCallback callback,
                               gpointer user_data);

Asynchronously creates a proxy for the D-Bus interface org.freedesktop.UDisks2.Manager.NVMe. See g_dbus_proxy_new() for more details.

When the operation is finished, callback will be invoked in the thread-default main loop of the thread you are calling this method from (see g_main_context_push_thread_default()). You can then call udisks_manager_nvme_proxy_new_finish() to get the result of the operation.

See udisks_manager_nvme_proxy_new_sync() for the synchronous, blocking version of this constructor.

Parameters

connection

A GDBusConnection.

 

flags

Flags from the GDBusProxyFlags enumeration.

 

name

A bus name (well-known or unique) or NULL if connection is not a message bus connection.

[nullable]

object_path

An object path.

 

cancellable

A GCancellable or NULL.

[nullable]

callback

A GAsyncReadyCallback to call when the request is satisfied.

 

user_data

User data to pass to callback .

 

udisks_manager_nvme_proxy_new_finish ()

UDisksManagerNVMe *
udisks_manager_nvme_proxy_new_finish (GAsyncResult *res,
                                      GError **error);

Finishes an operation started with udisks_manager_nvme_proxy_new().

Parameters

res

The GAsyncResult obtained from the GAsyncReadyCallback passed to udisks_manager_nvme_proxy_new().

 

error

Return location for error or NULL

 

Returns

The constructed proxy object or NULL if error is set.

[transfer full][type UDisksManagerNVMeProxy]


udisks_manager_nvme_proxy_new_sync ()

UDisksManagerNVMe *
udisks_manager_nvme_proxy_new_sync (GDBusConnection *connection,
                                    GDBusProxyFlags flags,
                                    const gchar *name,
                                    const gchar *object_path,
                                    GCancellable *cancellable,
                                    GError **error);

Synchronously creates a proxy for the D-Bus interface org.freedesktop.UDisks2.Manager.NVMe. See g_dbus_proxy_new_sync() for more details.

The calling thread is blocked until a reply is received.

See udisks_manager_nvme_proxy_new() for the asynchronous version of this constructor.

Parameters

connection

A GDBusConnection.

 

flags

Flags from the GDBusProxyFlags enumeration.

 

name

A bus name (well-known or unique) or NULL if connection is not a message bus connection.

[nullable]

object_path

An object path.

 

cancellable

A GCancellable or NULL.

[nullable]

error

Return location for error or NULL

 

Returns

The constructed proxy object or NULL if error is set.

[transfer full][type UDisksManagerNVMeProxy]


udisks_manager_nvme_proxy_new_for_bus ()

void
udisks_manager_nvme_proxy_new_for_bus (GBusType bus_type,
                                       GDBusProxyFlags flags,
                                       const gchar *name,
                                       const gchar *object_path,
                                       GCancellable *cancellable,
                                       GAsyncReadyCallback callback,
                                       gpointer user_data);

Like udisks_manager_nvme_proxy_new() but takes a GBusType instead of a GDBusConnection.

When the operation is finished, callback will be invoked in the thread-default main loop of the thread you are calling this method from (see g_main_context_push_thread_default()). You can then call udisks_manager_nvme_proxy_new_for_bus_finish() to get the result of the operation.

See udisks_manager_nvme_proxy_new_for_bus_sync() for the synchronous, blocking version of this constructor.

Parameters

bus_type

A GBusType.

 

flags

Flags from the GDBusProxyFlags enumeration.

 

name

A bus name (well-known or unique).

 

object_path

An object path.

 

cancellable

A GCancellable or NULL.

[nullable]

callback

A GAsyncReadyCallback to call when the request is satisfied.

 

user_data

User data to pass to callback .

 

udisks_manager_nvme_proxy_new_for_bus_finish ()

UDisksManagerNVMe *
udisks_manager_nvme_proxy_new_for_bus_finish
                               (GAsyncResult *res,
                                GError **error);

Finishes an operation started with udisks_manager_nvme_proxy_new_for_bus().

Parameters

res

The GAsyncResult obtained from the GAsyncReadyCallback passed to udisks_manager_nvme_proxy_new_for_bus().

 

error

Return location for error or NULL

 

Returns

The constructed proxy object or NULL if error is set.

[transfer full][type UDisksManagerNVMeProxy]


udisks_manager_nvme_proxy_new_for_bus_sync ()

UDisksManagerNVMe *
udisks_manager_nvme_proxy_new_for_bus_sync
                               (GBusType bus_type,
                                GDBusProxyFlags flags,
                                const gchar *name,
                                const gchar *object_path,
                                GCancellable *cancellable,
                                GError **error);

Like udisks_manager_nvme_proxy_new_sync() but takes a GBusType instead of a GDBusConnection.

The calling thread is blocked until a reply is received.

See udisks_manager_nvme_proxy_new_for_bus() for the asynchronous version of this constructor.

Parameters

bus_type

A GBusType.

 

flags

Flags from the GDBusProxyFlags enumeration.

 

name

A bus name (well-known or unique).

 

object_path

An object path.

 

cancellable

A GCancellable or NULL.

[nullable]

error

Return location for error or NULL

 

Returns

The constructed proxy object or NULL if error is set.

[transfer full][type UDisksManagerNVMeProxy]


udisks_manager_nvme_skeleton_new ()

UDisksManagerNVMe *
udisks_manager_nvme_skeleton_new (void);

Creates a skeleton object for the D-Bus interface org.freedesktop.UDisks2.Manager.NVMe.

Returns

The skeleton object.

[transfer full][type UDisksManagerNVMeSkeleton]

Types and Values

UDisksManagerNVMe

typedef struct _UDisksManagerNVMe UDisksManagerNVMe;

Abstract interface type for the D-Bus interface org.freedesktop.UDisks2.Manager.NVMe.


struct UDisksManagerNVMeIface

struct UDisksManagerNVMeIface {
  GTypeInterface parent_iface;

  gboolean (*handle_connect) (
    UDisksManagerNVMe *object,
    GDBusMethodInvocation *invocation,
    const gchar *arg_subsysnqn,
    const gchar *arg_transport,
    const gchar *arg_transport_addr,
    GVariant *arg_options);

  gboolean (*handle_set_host_id) (
    UDisksManagerNVMe *object,
    GDBusMethodInvocation *invocation,
    const gchar *arg_hostid,
    GVariant *arg_options);

  gboolean (*handle_set_host_nqn) (
    UDisksManagerNVMe *object,
    GDBusMethodInvocation *invocation,
    const gchar *arg_hostnqn,
    GVariant *arg_options);

  const gchar * (*get_host_id) (UDisksManagerNVMe *object);

  const gchar * (*get_host_nqn) (UDisksManagerNVMe *object);
};

Virtual table for the D-Bus interface org.freedesktop.UDisks2.Manager.NVMe.

Members

GTypeInterface parent_iface;

The parent interface.

 

handle_connect ()

Handler for the “handle-connect” signal.

 

handle_set_host_id ()

Handler for the “handle-set-host-id” signal.

 

handle_set_host_nqn ()

Handler for the “handle-set-host-nqn” signal.

 

get_host_id ()

Getter for the “host-id” property.

 

get_host_nqn ()

Getter for the “host-nqn” property.

 

struct UDisksManagerNVMeProxy

struct UDisksManagerNVMeProxy {
};

The UDisksManagerNVMeProxy structure contains only private data and should only be accessed using the provided API.


struct UDisksManagerNVMeProxyClass

struct UDisksManagerNVMeProxyClass {
  GDBusProxyClass parent_class;
};

Class structure for UDisksManagerNVMeProxy.

Members


struct UDisksManagerNVMeSkeleton

struct UDisksManagerNVMeSkeleton {
};

The UDisksManagerNVMeSkeleton structure contains only private data and should only be accessed using the provided API.


struct UDisksManagerNVMeSkeletonClass

struct UDisksManagerNVMeSkeletonClass {
  GDBusInterfaceSkeletonClass parent_class;
};

Class structure for UDisksManagerNVMeSkeleton.

Members